Explainer

The impedance coupon passed. Why does the routed channel fail?

A panel coupon isolates fabrication from the details of the actual route. Use that difference to work out whether a reflection comes from the stack-up, the measurement or the board layout.
Illustrative PCB routes and TDR responses comparing a flat panel coupon trace with a local reflection at a via in the routed channel.

Illustration: The Electronics Brief

A panel coupon can measure 50 Ω while the assembled channel still reflects enough energy to fail a test, because the coupon verifies a representative length of trace rather than the complete signal path. A passing result gives you a reference for the board build while you check the transitions the coupon did not reproduce, including launches, vias and places where the return current changes paths.

Compare the traces behind the numbers

Start by confirming that the coupon represents the failing route. It should use the relevant layer, reference plane arrangement, copper geometry and dielectric construction. For a differential route, include pair spacing and check that the measured quantity is differential impedance. A passing coupon for an outer layer does little to settle a fault on an inner layer with a different dielectric thickness.

Next compare the shape of the time domain reflectometer (TDR) traces. A sustained shift along a routed section points towards a change affecting that length, such as geometry or the reference plane arrangement. A short feature at a repeatable delay can be mapped to a particular via, connector launch or discontinuity in the return path. For example, a reflection 400 ps after the calibrated launch corresponds to about 30 mm along a trace with a propagation speed of 150 mm/ns. Divide the round-trip distance by two before matching it to a feature in the layout.

Account for the launch before blaming the board

A probe or connector launch can create its own reflection. Keep the same measurement reference plane when comparing boards and account for the fixture where the measurement method allows it. On a short trace, the launch and far end may leave too little flat region to extract a reliable impedance value. Polar Instruments recommends selecting a flat measurement region after the launch and before the far end when one exists, then using the same window for repeat manufacturing measurements.

If the coupon and controlled parts of the route agree, inspect the local feature the TDR identified. For example, around a signal via that changes reference planes, check where the return current crosses between those planes. Keep the coupon as the fabrication control and compare a channel that includes the revised via or launch with the original.

Sources: Polar Instruments: testing coupons versus built-in test traces; Polar Instruments: measuring short controlled impedance traces; The Electronics Brief: specifying controlled impedance on a PCB.