Explainer

Why an unpowered IC can wake up through its signal pins

Tracing back-power paths through I/O protection, interpreting Ioff limits and separating a clean shutdown from a rail that is merely disconnected.
Oscilloscope, multimeter and circuit boards on an electronics development bench

Illustrative image: Axel Richter on Unsplash

An IC can lose its intended supply and still receive current through a signal pin. When that pin connects to an active device on another rail, an internal protection path can feed the supposedly unpowered supply, leaving enough voltage to disturb reset, increase standby consumption or keep part of the circuit alive.

This becomes a system problem wherever power domains start and stop independently. A processor may remain active while a PHY sleeps, a communications module may watch for a wake event while its host is off, or a powered cable may remain attached after the main supply disappears. In each case, the signal connection bridges two different power states.

Follow the current into the rail

A common path is the diode between an I/O pin and the positive supply. With the supply at zero and the pin driven high, the diode can conduct into the rail. The resulting rail voltage depends on the source impedance and the load connected to it, so a small current can produce a surprisingly large voltage on a lightly loaded circuit.

That behaviour is not universal to every input. Some logic families remove the conventional positive clamp or use a different input structure to tolerate voltages above their supply. Output pins also need attention because their transistor structures can provide a path into the device even when its inputs are tolerant. Toshiba treats input tolerance, output tolerance and output power-down protection as separate functions, with different conditions attached to each.

An output-enable signal therefore cannot be assumed to solve a supply-off problem. A device may offer a high-impedance output while correctly powered yet provide no corresponding guarantee at VCC = 0 V. The electrical specification has to cover the state the circuit actually reaches.

Read the Ioff condition

The Ioff parameter describes leakage with the device powered down. In TI’s SN74LVC1G125 buffer, the electrical table specifies a maximum magnitude of 10 µA with VCC held at zero and an input or output at 5.5 V, across the stated temperature ranges. Its partial-power-down circuitry disables the output at zero supply, while its input protection avoids the standard positive clamp diode.

The supply condition is as significant as the leakage figure. A limit tested at zero volts does not, on its own, describe every point during a slow rail ramp. In this buffer’s application guidance, TI separately recommends pulling the active-low output-enable pin to VCC to keep the output disabled during power-up and power-down, with the resistor chosen to suit the controlling driver.

For a two-supply translator, the equivalent check includes both supply pins. TI’s TXV010x RGMII translators provide partial-power-down isolation when either supply is held at zero, alongside features intended to handle sequencing between Ethernet devices. That protects a different boundary from merely accepting a higher logic voltage while both sides are operating.

A signal switch needs protection too

Adding a switch between the live and sleeping domains only works when the switch retains isolation in the same power state. TI’s powered-off protection application brief shows how an unprotected switch can receive current through its own I/O diode, energising its supply and allowing a signal to pass to the downstream circuit.

In the same brief, a protected switch maintains high impedance at zero supply. TI gives the TMUX136 as an example with a maximum I/O leakage of 10 µA at VCC = 0 V and an I/O voltage of 3.45 V. The protection is specified within that voltage range; it is not permission to apply arbitrary fault voltages.

Check the rail during the transition

A useful bench check starts with the intended supply removed and the external signal sources still active. Measuring the affected supply pin while disconnecting those sources in turn can identify the path, but an oscilloscope is needed to see what happens during shutdown and restart rather than only after the rail has settled.

The measuring instrument can change the result. As an illustrative calculation, a 10 MΩ probe at 1 V draws only 0.1 µA. A 10 µA leakage path could therefore support that reading on an otherwise lightly loaded rail, although it would not necessarily operate the IC. The observed voltage becomes more informative when considered alongside the available current, reset state and actual rail load.

Pull-ups also form part of that circuit. A bus pulled to an always-on supply can continue feeding a sleeping device after the main controller has stopped transmitting, while a debug connection can add a path absent from normal operation. Checking the pull-up supply and attached interfaces alongside the signal direction avoids treating the processor’s firmware state as proof that every pin is electrically inactive.

For a design with several domains, the test set can be written as combinations of supply and signal states: host on with peripheral off, the reverse arrangement, shutdown, restart and cable insertion. Recording rail voltage and leakage for each state gives the Ioff and isolation specifications a direct counterpart in the assembled hardware.

Sources: TI: RGMII power sequencing and translator isolation; TI: SN74LVC1G125 datasheet, revision U; TI: powered-off protection in signal switches, SCDA015C; Toshiba: input/output tolerance and power-down protection.

Continue reading