Toshiba gives motor drives a 500 ns overcurrent warning

The DCA121102 reports an overcurrent condition in 500 ns typical, alongside the normal analogue path used for motor current measurement.
Toshiba isolation amplifier beside a motor and an industrial robot graphic.

Toshiba’s DCA121102 brings two jobs normally treated separately into one isolation amplifier. It passes a continuous analogue measurement from the high voltage side of a drive to the low voltage controller and gives that controller a faster warning when the current goes beyond normal operation. Toshiba has started volume production of the part and of the DCA121002, which provides the same measurement function without the faster overcurrent feedback.

Both devices accept a differential input in the ±250 mV linear range and output a differential analogue signal. In a shunt based design, the choice of resistance therefore sets how much of that input range normal motor current will use and how much headroom remains as current rises. The two amplifiers have the same typical analogue propagation delay of 1.6 µs. Toshiba quotes 500 ns typical for overcurrent feedback on the DCA121102. That is the amplifier’s detection and reporting time; the controller, gate driver and power switches still determine the time between the warning and interruption of the current.

The amplifier has to preserve the small shunt signal while the voltage on one side of the isolation barrier can change quickly. Toshiba specifies a typical signal to noise ratio of 85 dB at 25 °C with 5 V and 3.3 V supplies and a minimum common mode transient immunity of 100 kV/µs under its stated conditions. The first figure describes noise in the measurement and the second describes how the amplifier tolerates a transient across the barrier.

The SOIC8-W package provides at least 8 mm creepage, with a minimum 5,000 V RMS isolation withstand specified at 25 °C. Each side has a recommended supply range of 3.0 V to 5.5 V across −40 °C to +125 °C. The shared package lets the two variants address the same mechanical footprint; it does not, on its own, establish electrical interchangeability with another supplier’s part.

Toshiba’s DCA121x02 isolation amplifier in the company’s motor drive launch artwork. Resized and encoded as JPEG without cropping.

Sources: Toshiba launch and specifications; Toshiba English release.