Bourns fits an 8 mm isolation path into a 3 W flyback transformer

Image: Bourns
Bourns’ new 3 W flyback transformer puts an 8 mm creepage path into a surface mount package intended for high isolation automotive supplies. The HVMA03F30A-LP8S is rated for 1,000 V working voltage and uses insulation material with a comparative tracking index of at least 600, putting it in material group I.
The part is aimed in part at isolated gate drive supplies. In a flyback converter the primary stores energy while its switch conducts and transfers that energy to the secondary during the off period, so primary inductance and peak current govern how much energy is available per cycle. Bourns specifies 30 µH ±10%, measured at 100 kHz and 0.1 V, a 1:1 turns ratio with ±3% tolerance and a switching frequency range from 12 kHz to 350 kHz. The turns ratio does not on its own set the output voltage of a flyback supply.
The 8 mm figure describes the creepage path on the component. Copper routing or conductive hardware nearby can shorten the corresponding path once the transformer is mounted. The data sheet also lists a 2,150 V DC dielectric test for 60 seconds; that is distinct from the 1,000 V working voltage rating. Bourns lists the part as AEC-Q200 compliant and specifies operation from −40 °C to +125 °C with the transformer’s temperature rise included.
Sources: Bourns launch bulletin; Bourns data sheet.