News

The TVS clamps at the connector. Why does the IC still see an overshoot?

Two measurements on the same transient can separate the suppressor’s clamping behaviour from the voltage developed in the layout.
Oscilloscope probes measuring a printed circuit board.

A suppressor can clamp cleanly at the connector while the protected input several centimetres away still sees an overshoot. The TVS conducts between its own pads, but the voltage at the IC is measured against a different return point. During a fast transient, inductance in the copper between them can account for part of the difference. Inductance in a long probe ground can produce a similar-looking peak on the screen, which makes the choice of measurement points as important as the choice of suppressor.

Capture both voltages against their own returns

Use a repeatable test and measure across the TVS pads first. Then capture the voltage between the protected IC pin and its local return, keeping the pulse and probe setup consistent. Short measurement loops help keep probe-induced ringing out of the comparison. On a floating or mains-referenced assembly, use a differential measurement arrangement rated for the circuit and the transient; an earth-referenced scope ground can short a point that is not at earth potential.

Compare when the peaks occur and what the traces do after the first edge. A higher voltage at both points through the body of the pulse directs attention to the clamp voltage at the actual pulse current and waveform. The reverse standoff rating describes normal operation and should not be used in place of the datasheet’s clamp figure. A higher first peak at the IC with a similar later clamp level is consistent with an extra voltage along the PCB path or a probe artefact. The shape is a clue; the two captures do not identify a particular via by themselves.

Trace where the surge current returns

There are two routes to inspect: the connection from the entry point to the TVS and the return path from the TVS to the reference used by the equipment. A long branch to the suppressor can leave inductance between the connector and the device doing the clamping. A return that shares copper with the IC can also move the local reference during the transient. TI’s layout guide treats these as distinct parasitic paths and recommends placing the suppressor near the entry point with a short return.

For scale, 5 nH at a current slew rate of 1 A/ns gives 5 V from L × di/dt. That is just the contribution of the example inductance at that instant; the total voltage at the pin still has to be measured. After altering routing or the suppressor, repeat the two captures under the same conditions. The peak and duration at the IC, together with the applicable device limits, are the evidence to compare with the original result.